The KRD13-HC High-Acceleration Sensor Calibration System is a vertical impact calibration system featuring an innovative design, a high degree of automation, simple operation, and easy maintenance. It is characterized by its compact size, light weight, adjustable pulse duration, rational structural design, and high reliability.
The system can be used to perform various conventional classical impact tests for measuring and determining the impact resistance of products. It can also serve as a standard source for the calibration, impact testing, and measurement of vibration and shock sensors. The system is suitable for high-range impact calibration, verification, and testing of vibration sensors and shock sensors.
Applicable Standards
• IEC 60068-2-27:2008 — Environmental testing — Part 2-27: Tests – Test Ea and guidance: Shock
• MIL-STD-810, Method 516 — Environmental Engineering Considerations and Laboratory Tests— Shock
• JJG 541-88 — Verification Regulation for Drop Impact Testing Machines
• JJF 2076-2016 — Verification System for Measuring Instruments for Shock Accelerometers — Requirements for Shock Standards Using the Acceleration Comparison Method
• JJF 1537-2015 — Calibration Specification for Dynamic Characteristics of Gyroscopes — Requirements for Shock Testing Machines
Get a quote
Main System Functions
Windows-Based Stable Control System
Equipped with a fully automatic remote control interface. The operator only needs to enter the required test parameters, and the shock control and measurement system can accurately perform the impact test. It supports single-impact and continuous-impact testing, as well as multiple impact modes for convenient user selection.

High-Strength Shock Table
The alloy-forged shock table features high strength and hardness, enabling it to withstand high-load tests and high-acceleration impact events.


Advanced Pressurized Impact Mode
The pressurized impact cylinder and pneumatic energy-storage system work in conjunction with the pneumatic lifting mechanism to provide impact energy beyond that achievable by conventional free-fall impact systems, meeting requirements for various high-impact final velocities.
Digital Closed-Loop Control of Impact Energy
The pneumatic impact energy is adjusted through digital feedback closed-loop control and can be fully set and executed through the PLC control interface. The impact energy is conveniently adjusted by changing the air pressure, providing easy operation and high efficiency.
Multiple Impact Intensity Tests
By replacing different waveform generators, the system can perform half-sine impact tests with different impact intensities.

Low-Friction Floating Bearing Guidance
The shock table uses floating bearings for free guidance, resulting in low frictional energy loss. After obtaining the required energy, the waveform generator produces the impact pulse freely, with no secondary impact and excellent repeatability.
Advanced Drive System
The system adopts a fully pneumatic drive system, featuring a simple structure, high reliability, and clean operation without pollution, helping maintain a clean testing environment.
High Efficiency and High Precision
The advanced pneumatic drive and control system significantly improve the repeatability and consistency of impact testing.
User-Friendly Operation
By adjusting the air pressure and selecting elastic pads with different stiffnesses for the impact waveform generator, the impact peak acceleration, pulse duration, and rate of velocity change can be adjusted to achieve different impact test conditions.
Main Technical Specifications
Table 3-1 Main Technical Specifications of the Equipment
Specification | ||
Rated Load | 500g | |
shock Pulse Waveform | Half-sine wave | |
Pulse Form | Gas-gun pressurized impact | |
Max. Impact Peak Acceleration | 200,000 m/s² | |
Measurement Range (Peak) | Pulse Duration | |
50–20,000 m/s² | 0.20–10ms | |
20,000–100,000 m/s² | 0.05–0.20ms | |
100,000–200,000 m/s² | 0.02–0.05ms | |
Dimensions (L×W×H) | 400mm×400mm×1200mm | |
Total Weight | 30kg | |
General Requirements | ||
Installation | Foundation-free | |
Power Supply | 220VAC±10% 50Hz | |
Environmental Conditions | Temperature (°C) | 0 ~ 40 |
Humidity (25°C) | < 85% | |
Stable Air Source (MPa) | ≤ 0.8 | |