KRD31 Constant Acceleration Tester-Arm Type

Product description

KRD31 series constant acceleration tester are used to test articles under extreme acceleration conditions based on standard like MIL-STD-810F, MIL-STD-202 and IEC68-2-7.

It is most suitable for testing electronic components or devices. Under high g effect on microcircuits, to check adaptability and reliability of wiring and the internal structures. It may expose mechanical and structural defects that are not found with vibration and shock tests.

Download Document Get a quote

KRD31 series  constant acceleration tester are used to test articles under extreme acceleration conditions based on standard like MIL-STD-810F, MIL-STD-202 and IEC68-2-7.

 

It is most suitable for testing electronic components or devices. Under high g effect on microcircuits, to check adaptability and reliability of wiring and the internal structures. It may expose mechanical and structural defects that are not found with vibration and shock tests.

 

Technical Specifications


          Model

Parameters

KRD

3130

KRD

3150

KRD

31100

KRD

31100A

KRD

31200

KRD

31500

KRD

311000

KRD

311500

Max. Load

(kg)

30

50

100

200

500

1000

1500

Installation Platform Size (mm)

500×500

600×600

700×700

800×800

1000×1000

1200×1200

1500×1500

Acceleration

(g)

3100

350

Acceleration Accuracy (%)

≤±3

Specimen Installed Radius (mm)

1000

1200

1650

2150

2600

3000

5400

6250

Max Turning Diameter (mm)

2500

3000

4000

5000

6000

7000

12000

14000

Launch/Stop Time

(Min)

≤3

≤5

≤8

≤10

Continues Working Time (min)

60

30

Inner Diameter of

Foundation (mm)

Φ3000

Φ3500

Φ4500

Φ5500

Φ7000

Φ8500

Φ14000

Φ16000

Slip Ring

Optional according to user requirements

Weight

(kg)

2500

4000

5000

5500

7000

8000

10000

12000

Power Supply

3-phase AC 380V±10 50Hz

Control Mode

Fully closed-loop digital network (remote) automatic control + manual control

Working

Environment

Temperature range 040, Humidity≤80% (non-condensing)

Installation Condition

According to the foundation drawings provided by the manufacturer

Standards

MIL-STD-810F  IEC68-2-7    MIL-STD-202   MIL-STD-750  MIL-STD-883

Note: 1. The parameters in the table are for reference only, and the parameters agreed upon by the supplier and the buyer shall prevail.

2. In addition to providing electrical signals, the slip ring can also optionally add transmission functions such as oil, gas, special signals, Ethernet, and RF signals.


Application Video


×